Tyler
Member
Our Triumph 1-m base died in the field before being able to "stop" the base. The base was turned on the following day and was still running and needed me to press the "stop and download" button. Once I had downloaded the base file I tried to DPOS and all but one of my points is on FLT or STN although all of these points were in open sky with no issues getting a fix. There are also large shifts in the positions of the measurements gathered with the Triumph LS and they only show RTK and PPK (standalone) options for coordinates.
I've tried redownloading the base file and reprocessing but I have the same issue.
Is there a method to fix these issues so that I can correctly post-process my points? It says the raw data file for the base is too large to attach on this post. Let me know if there is any other info needed to determine the problem.
I've tried redownloading the base file and reprocessing but I have the same issue.
Is there a method to fix these issues so that I can correctly post-process my points? It says the raw data file for the base is too large to attach on this post. Let me know if there is any other info needed to determine the problem.